Oracle Data Guard Startup & Shutdown Steps

In this article we will look at Oracle Data Guard startup and shutdown sequence. You must follow proper shutdown order to perform a graceful shutdown.


Make sure you have permission from application owner / database architect to perform primary shutdown.


Data Guard Shutdown Sequence


Stop log apply service or MRP and shutdown the standby

SQL> ALTER DATABASE RECOVER MANAGED STANDBY DATABASE CANCEL;
SQL> SHUT IMMEDIATE;

Stop log shipping from primary and shutdown primary database

SQL> ALTER SYSTEM SET log_archive_dest_state_2='DEFER';
SQL> SHUT IMMEDIATE;


Data Guard Startup Sequence


Startup primary database and enable log shipping

SQL> STARTUP;
SQL> ALTER SYSTEM SET log_archive_dest_state_2='ENABLE';

Startup standby and enable log apply service or MRP

SQL> startup nomount;
SQL> alter database mount standby database;

SQL> ALTER DATABASE RECOVER MANAGED STANDBY DATABASE DISCONNECT FROM SESSION;

Enjoy!